How the integrating sphere measures LED lights

Posted By HOPOO   |   02 Sep, 2022   |   435 views
How the integrating sphere measures LED lights

The integrating sphere is a cavity sphere whose inner wall is coated with white diffuse reflective material, also known as photometric sphere, luminous flux sphere, etc. One or several window holes are opened on the spherical wall, which are used as light inlet holes and receiving holes for placing light receiving devices. The inner wall of the integrating sphere should be a good spherical surface, and it is generally required that its deviation from the ideal spherical surface should not be greater than 0.2% of the inner diameter. The inner wall of the sphere is coated with an ideal diffuse reflection material, that is, a material with a diffuse reflection coefficient close to 1.

The working principle of the integrating sphere :
The light is collected by the integrating sphere through the sampling port as shown in the figure below. After multiple reflections inside the integrating sphere, the light will exist very uniformly at various positions inside the integrating sphere.

When using the light in the integrating sphere to measure, it can make our measurement results more reliable. The advantage of using the integrating sphere structure is that the shape of the light, the angle of divergence, and the responsivity of different positions on the detector can be reduced and eliminated. measurement errors caused by differences.

How does the integrating sphere measure LED lights?

1. Preparation: Prepare an integrating sphere of suitable size, a standard light source with a luminous flux close to the light source of the lamp, and an ambient temperature of about 25 degrees to avoid wind blowing into the integrating sphere;

2. Inspection: Install the standard light source into the integrating sphere, connect the current source and power meter, and then light the standard light source. In the integrating sphere software operation interface, adjust to continuous test, until the luminous flux reaches stability, record its luminous flux value;

3. Calibration: The operation of calibration is similar to that of checking, except that calibration is performed before lighting the standard light source. After the luminous flux is stable, input the standard color temperature and standard luminous flux of the standard light source in the integrating sphere software operation interface, and then click to start calibration, the integrating sphere tester will automatically complete the calibration;

4. Test the sample: Install the sample into the integrating sphere, light the sample, close the integrating sphere, and start the test. After the luminous flux is stable, record the value.

Hangzhou Hopoo Light&Color Technology Co., Ltd. focuses on the production, research and development and sales of lighting and electrical testing instruments. The whole series of products are developed and produced in strict accordance with the requirements of ISO9001:2015; all products meet the requirements of CIE; in addition, All products of hopoocolor have passed CE certification and obtained the qualification to export to the European Union. The main products include goniophotometer, integrating sphere, spectroradiometer, illuminometer, colorimeter, and LED test instruments. 

If you want to know more technical or product information, please feel free to contact us.
Sales Department: 86 18069445092, Sales_fob@hopoocolor.com

MENU

BEST SALE

HANGZHOU HOPOO LIGHT&COLOR TECHNOLOGY CO.,LTD.

Welcome to Hopoocolor, a global leader in lighting optical detection built on innovation, collaboration and engineering excellence. HopooWhy Hopoo haveWithHopoo successfully developed a series of multi-functional optical testing equipm …

Read More

HOT PRODUCTS

  • HPG2000 Vertical Version Goniophotometer

    HPG2000 is a Goniophotometer, a moving mirror Goniophotometer recommended by the International Commission on Illumination CIE70 document.

    Read More
  • OHSP-350 Portable Spectral irradiance colorimeter

    OHSP-350 Spectral irradiance colorimeter, integrated spectrum, CCT, CRI, Lux, irradiation .etc parameters in one.

    Read More
  • OHSP350LFA PST SVM Flicker Spectrometer

    OHSP350LFA PST SVM Flicker Spectrometer

    Read More
  • Goniophotometer

    According to the requirements of CIE, IESNA and national standards, we have achieved testing methods as B-(B、A-a and C-y through rotating lamps. It is used to test the spatial light intensity distribution as well as variety luminosity parameter of indoor spotlight, cast light lamp and street light.

    Read More
  • HPCS300 Mini Spectrometer

    HPCS300 Spectral Illuminance Sensing Module ,adopt advanced technology, used in production line ,achievement On-line analysis of light and color parameters, USB interface to output test result, open USB communication, it can use by self-programme ,read spectrum data、CCT、Lux etc

    Read More
  • CX-200 imaging luminance meter&Photometer

    Imaging Luminance meter is a comprehensive solution for thequality control of indoor and outdoor lighting products, illuminated symbols, automotive, aerospace and street luminance.

    Read More
  • OHSP350UVS Spectrometer 180-400nm customized model

    OHSP350UVS customized model 180nm-400nm

    Read More
  • HPCS-300P Mini PPFD Spectrometer

    HPCS-300P Mini PPFD Spectrometer,use with pc software.

    Read More
  • CXCSG-02 Imaging Colorimeter(Production Line)

    For the design of automotive lighting accessories module assembly and injection molded parts, the brightness L, color coordinates X, Y, color temperature, dominant wavelength and other parameters of each lighting component can be measured.

    Read More
  • Goniophotometer

    According to the requirements of CIE, IESNA and national standards, It is used to test the spatial light intensity distribution as well as variety luminosity parameter of indoor spotlight, cast light lamp and street light. Add Grow light PPF parameters.

    Read More
  • HPCS6500UV Spectroradiometer

    HPCS6500UV Spectroradiometer test system is a multifunctional comprehensive test system which integrates photometric parameters, colorimetric parameters, electrical parameters, etc. The product adopts modular and integrated design, which makes the structure compact. With a 10.1-inch LCD screen

    Read More
  • Goniophotometer

    According to the requirements of CIE, IESNA and national standards, we have achieved testing methods as B-(B、A-a and C-y through rotating lamps. It is used to test the spatial light intensity distribution as well as variety luminosity parameter of indoor spotlight, cast light lamp and street light.

    Read More